Omron H5CX-A-N is a digital timer relay (SPDT) 48mm x 48mm for flush mounting to the control panel enclosure front cover. Input voltage 110 to 240 VAC.

Rated supply voltage 100 to 240 VAC
Time range 0.001 s to 9999 h
Input method No-voltage (NPN)/Voltage (PNP) input (selectable)
Control output Time-limit contact: SPDT
Display mode Elapsed time (UP) and remaining time (DOWN) (selectable)
Display method 7-segment negative transmissive LCD 4 digit
External connection method Screw terminal

Specifications

Rated supply voltage 100 to 240 VAC (50/60 Hz)
Operating voltage range 85 to 110% of rated supply voltage
Power consumption Approx. 6.2 VA
Time ranges(Number of ranges) 10
Time ranges 0.001 to 9.999 s
0.01 to 99.99 s
0.1 to 999.9 s
1 to 9999 s
0.1 to 999.9 min
1 to 9999 min
0.1 to 999.9 h
1 to 9999 h
1 s to 99 min 59 s
1 min to 99 h 59 min
Input method No-voltage (NPN)/Voltage (PNP) input (selectable)
No-voltage input Solid state input Short-circuit (ON) impedance: 1 kΩ max. (Leakage current (0 Ω): Approx. 12 mA)
Short-circuit (ON) residual voltage: 3 V max.
Open circuit impedance: 100 kΩ min.
(The DC voltage must be 30 VDC max.)
Contact input Use contact which can adequately switch 5 mA at 10 V
Applicable two-wire sensor Leakage current: 1.5 mA max.
Switching capacities: 5 mA min.
Residual voltage: 3.0 VDC max.
Operating voltage: 10 VDC
Voltage input High level: 4.5 to 30 VDC
Low level: 0 to 2 VDC (Input resistance 4.7 kΩ)
Output modes A: Signal ON delay (Ⅰ)
A-1:Signal ON delay (Ⅱ)
A-2: Power ON delay (Ⅰ)
A-3: Power ON delay (Ⅱ)
b: Repeat cycle (Ⅰ)
b-1: Repeat cycle (Ⅱ)
d: Signal OFF delay
E: Interval
F: Cumulative
Z: ON/OFF-duty adjustable flicker
S: Stopwatch
toff: Flicker OFF start (Ⅰ)
ton: Flicker ON start (Ⅰ)
toff-1: Flicker OFF start (Ⅱ)
ton-1: Flicker ON start (Ⅱ)
Control output (Contact output) Time-limit contact: SPDT
Resistive load: 5 A at 250 VAC/30 VDC (cosφ = 1)
Minimum applicable load: 10 mA at 5 VDC (failure level: P Reference value)
Reset system Power reset (depending on output mode)/Automatic reset (depending on output mode)/External reset/Manual reset
Power reset Minimum power-opening time: 0.5 s (except for A-3, b-1, F, ton-1 and toff-1 mode)
Timer mode Elapsed time (UP) and remaining time (DOWN) (selectable)
Display method 7-segment negative transmissive LCD 4 digit
Character height Present value: 12 mm (Red, green or orange programmable)
Set value: 6 mm (green)
Key protect method Key protect Switch
Memory backup method EEP-ROM (number of writes: 100,000 operations min., Service life: 10 years min.)
Ambient temperature (Operating) -10 to 55℃ (with no freezing or condensation)
When mount timer side by side: -10 to 50℃ (with no freezing or condensation)
Ambient temperature (Storage) -25 to 70℃ (with no freezing or condensation)
Ambient humidity (Operating) 25 to 85%
Accuracy of operating time Power-ON start: ±0.01% ±0.05 s max. (The values are based on the set value.)
Signal start: ±0.005% ±0.03 s max. (The values are based on the set value.)
Setting error Power-ON start: ±0.01% ±0.05 s max. (The values are based on the set value.)
Signal start: ±0.005% ±0.03 s max. (The values are based on the set value.)
Influence of voltage Power-ON start: ±0.01% ±0.05 s max. (The values are based on the set value.)
Signal start: ±0.005% ±0.03 s max. (The values are based on the set value.)
Influence of temperature Power-ON start: ±0.01% ±0.05 s max. (The values are based on the set value.)
Signal start: ±0.005% ±0.03 s max. (The values are based on the set value.)
Insulation resistance Between current carrying terminals and exposed non-current carrying metal parts: 100 MΩ min. (at 500 VDC)
Between non-continuous contacts: 100 MΩ min. (at 500 VDC)
Dielectric strength Between current carrying metal parts and non-current carrying metal parts: 2000 VAC 50/60 Hz 1 min
Between control output, and power supply/input circuit: 2000 VAC 50/60 Hz 1 min
Between non-continuous contacts: 1000 VAC 50/60 Hz 1 min
Between operating power circuit and input circuit: 2000 VAC 50/60 Hz 1 min
Impulse withstand voltage Between power terminals: 5 kV
Between current carrying terminals and exposed non-current carrying metal parts: 5 kV
Noise immunity Between power terminals: ±1.5 kV
Between input terminals: ±600 kV
square-wave noise by noise simulator, pulse width: 100 ns/1 µs, 1-ns rise
Static immunity Mulfunction: 8 kV, Destruction: 15 kV
Vibration resistance Destruction: 10 to 55 Hz, 0.75 mm single amplitude each in 3 directions for 2 h
Malfunction: 10 to 55 Hz 0.35 mm single amplitude each in 3 directions for 10 min
Shock resistance Destruction: 300 m/s**2, 3 times each in 3 axes each directions
Malfunction: 100 m/s**2, 3 times each in 6 directions
Life expectancy Electrical: 100,000 operations min. (5 A at 250 VAC resistive load at 1800 operations/h, 23 ℃)
Mechanical: 10 million operations min. (under no load at 1,800 operations/h, 23 ℃)
Degree of protection IEC IP66, UL508 Type 4X (indoors) (only panel surface, when using the Y92S-29 Waterproof Packing and Y92F-30 Flush Mounting Adapter)
Mounting method Flush mounting
External connection method Screw terminal
Case color Black (Munsell N1.5)
Attachment Flush mounting adapter, waterproof packing, label for DIP switch settings, terminal covers
Accessory (sold separately) Soft Cover: Y92A-48F1
Hard Cover: Y92A-48
Flush mounting adapter: Y92F-30/Y92F-45
Waterproof rubber packing: Y92S-29
Replacement Front Panel: Y92P-CXT4S/Y92P-CXT4G/Y92P-CXT4B
Weight Main Unit: Approx. 115 g

Resources