Omron MKS2P 120 VAC Relay W/ Lockable Test Button

CAD $24.49
Part Number:
MKS2PIN AC120
Weight:
0.20 LBS
Shipping:
Calculated at Checkout

Description

Description:

 Omron MKS2PIN 120VAC relay. 8 PIN round. Varistor model with lockable test button, plug-in type, Built-in indicator.

Features:

  • Same mounting and internal wiring as the previous Super MK Relays
  • Built-in mechanical indicator enables checking contact operation.
  • All materials are RoHS compliant.
  • UL and IEC (TÜV) certification

Specs:

Product classification Monostable relays
Built-in LED indicator and varistor type (AC coil)
Coil ratings 120 VAC
Coil resistance 4480 Ohm
Release voltage (Reset voltage) 25% Min. (50 Hz), 30% Min. (60 Hz)
Operate voltage (Set voltage) 80% Max.
Max. voltage 110% (of rated voltage)
Power Consumption Approx. 2.3 VA at 60 Hz Approx. 2.7 VA at 50 Hz
Min Voltage to Operate 70%
Max Voltage 110%
Contact Rated Load (resistive)

NO 10 A, 250 VAC 10A, 30 VDC

NC 5 A, 250 VAC 5 A, 30 VDC

Contact Rated Load (Inductive)

7 A, 250 VAC

Contact Type DPDT
Contact method Single
Contact material Contact body material: Ag alloy
Contact finish: Nothing
Contact rated load 250 VAC 10 A (NO contact: Resistive load)
250 VAC 5 A (NC contact: Resistive load)
250 VAC 7 A (NO contact: Inductive load (cos phi = 0.4))
250 VAC 7 A (NC contact: Inductive load (cos phi = 0.4))
30 VDC 10 A (NO contact: Resistive load)
30 VDC 5 A (NC contact: Resistive load)
Maximum switching voltage

250 VAC (NO contact: Resistive load)
250 VAC (NC contact: Resistive load)
250 VAC (NO contact: Inductive load (cos phi = 0.4))
250 VAC (NC contact: Inductive load (cos phi = 0.4))
250 VDC (NO contact: Resistive load)
250 VDC (NC contact: Resistive load)

Maximum switching current AC: 10 A (NO contact: Resistive load)
AC: 10 A (NC contact: Resistive load)
AC: 10 A (NO contact: Inductive load (cos phi = 0.4))
AC: 10 A (NC contact: Inductive load (cos phi = 0.4))
DC: 10 A (NO contact: Resistive load)
DC: 10 A (NC contact: Resistive load)
Maximum switching power AC: 2500 VA (NO contact: Resistive load)
AC: 1250 VA (NC contact: Resistive load)
AC: 1750 VA (NO contact: Inductive load (cos phi = 0.4))
AC: 1750 VA (NC contact: Inductive load (cos phi = 0.4))
DC: 300 W (NO contact: Resistive load)
DC: 150 W (NC contact: Resistive load)
Failure rate

10 mA at 1 VDC (failure level: P Reference value)

Ambient temperature Operating: –40 to 60°C (with no icing or condensation)
Ambient humidity Operating: 5% to 85%
Contact resistance Max. 100 mOhm, Measuring the voltage drop across the contacts by applying test voltage/current as 5 VDC 1 A
Max.operating frequency (Mechanical) 18000 opn./h
Max.operating frequency (Electrical) 1800 opn./h (under rated load)
Endurance (Mechanical)) 5000000 operations Min.
Endurance (Electrical) 100000 operations Min.
Protective structure Closed type (cover)
Terminal structure Plug-in

 

 

MK-S Features 7 MK-S_Features1

Resources:

Manufacturer's Website

(with no icing or condensation)